TEL 1P UTP
1 NC none
PROFINET
1 1 1
2 NC none 2 2 1
3 NC none 3 3 2
4 4 1 4 NC none
5 5 1 5 NC none
6 NC none 6 6 2
7 NC none 7 NC none
8 NC none 8 NC none
S NC S S
PROFINET CR
1 3 1
2 6 1
3 1 2
4 NC none
5 NC none
6 2 2
7 NC none
8 NC none
S S
S = shield
NC = not connected
Creating/Changing Wiring Denitions
Here, too, you can create your own versions, although you can only do so by changing an ex-
isting denition.. It is useful to note the pin/pair assignment of the wiring version being created
in advance.
After selecting a wiring denition to be changed, you will be taken to the Name menu. A unique
wiring name, such as “568C,” can be entered here. There are 15 available character slots. At the
ashing cursor position, the ▲ and ▼ keys can now be used to scroll through the alphabet, all
digits 0–9 and an empty position. The desired digit or letter at the cursor position can be selected
with SEL.
Once the name has been entered, conrm with SEL. The Connections menu will open, where
the PIN is assigned to the PIN and wire pair as corresponds to the wiring version. This assign-
ment is necessary both for recognition of the correct assignment in the tested cable and of split
pairs with regard to crosstalk and for good/bad information after a successful test. The scroll bar
is set to Pin 1.
Select with SEL, which will bring you to the Connection menu for Pin 1. Now the possible se-
lections of all 8 pins that can be assigned to Pin 1 will appear. Use the ▲ and ▼ keys to select
the correct pin with SEL. The next step is the Pair menu, where you can assign the selected pins
to a pair with SEL.
You will now be back in the Connections menu, where you can see the assignment of the Pin
1. Use the ▼ key to move the scroll bar to the next item, and continue with the assignment as
before.
If you create any incorrect assignments, you can only overwrite them. Alternatively, you can
select the Device Settings > Reset to Factory Settings menu item. This will reset all changed
wiring denitions.
> Remote Unit ID
The KE7010 remote units required for correct and quick cabling verication are included with
No. 32 to simplify inventory management. Under Main Menu > Settings > Test Settings > Re-
mote Unit, a connected remote unit can simply be reprogrammed to the desired number. After
changing the number, we recommend writing the new number in the space provided on the back
of the device.