Use and Care Manual

WARNINGS AND SAFETY RULES
!
LOCATION
PARTS DESCRIPTION
ELECTRICAL
ASSEMBLY INSTRUCTIONS
WARRANTY
CLEANING AND MAINTENANCE
TECHNICAL SPECIFICATIONS
TROUBLESHOOTING
REMOTE CONTROL
USE AND OPERATION
!
CAUTION
SAVE AND READ THESE IMPORTANT INSTRUCTIONS
Read all instructions carefully before setting up and operating this unit. This manual
was designed to provide you with important information needed to setup, operate,
maintain, and trouble-shoot your cooler. Failure to follow these instructions may dam-
age and/or impair its operation and void the warranty.
Owners Manual
Port-A-Cool, LLC • 709 Southview Circle • Center, TX 75935
www.kuulaire.com • 1-888-999-6511
WARNINGS AND SAFETY RULES
!
LOCATION
PARTS DESCRIPTION
ELECTRICAL
ASSEMBLY INSTRUCTIONS
WARRANTY
CLEANING AND MAINTENANCE
TECHNICAL SPECIFICATIONS
TROUBLESHOOTING
REMOTE CONTROL
USE AND OPERATION
!
Made in China
115V 220V
Symptom Possible Cause Possible Solution
No discharge of air
Cord is not plugged in
Power is not on
Make sure cord is plugged in and try to turn the unit on pressing
buttons on control panel and remote control
Check the circuit breaker or check GFCI reset button
The unit will not
turn off
Damaged PCB
Remote Control Batteries
Calcium Build-up in Blower
Try to use remote control to see if unit responds
Check batteries
Deep clean unit — remove calcium debris
Unit is making noise Calcium Build-up in Blower Deep clean unit — remove calcium debris
Not cooling
Low/No Water
Water Level Sensor is stuck
Check water level
Drain/rell with fresh water and/or clean water tank
Odor Emission
Brand new unit
Old unit with algae
Brand new media will initially emit an odor which will dissipate
within a week of initial use
If the unit is not new, there may be an algae issue - replace the rigid
media pads and clean pads regularly
Water droplets coming
out of air outlet
Calcium saturated water
Clogged media
Drain water, deep clean and clean the media.
Media may need to be replaced.
1. Control Panel
2. Horizontal Louvers
3. Water Level Gauge
4. Caster
Model PACKA34
and PACKA342205060
Model PACKA44
and PACKA442205060
WARRANTY
For one year from date of installation, Port-A-Cool, LLC, warrants any original
component part or parts of the KuulAire
®
evaporative unit found, upon examination
by factory authorized personnel, to be defective in material or workmanship. Due to
warranty limits placed on our component parts by the original manufacturers, our
warranty is limited on manufactured units and their original component parts, as well
as replacement parts to a total of one (1) year after the date of installation.
If said equipment develops such defects within this period, it will be repaired or
replaced at our option. For breach of any implied or written warranty on this product,
Port-A-Cool, LLC, shall not be liable for any incidental or consequential damages.
This warranty is declared void if the equipment is found to have been misused, abused
or tampered with by unauthorized personnel. Do not use cooler cleaners, cooler treat-
ments, or other additives in this portable evaporative cooler. The use of any of these
products will void your warranty and may impair the life of your evaporative cooler.
All transportation charges on parts submitted for replacement or repair under this
warranty must be borne by the purchaser.
To obtain service under this warranty, contact the dealer where you purchased your
evaporative cooler. As a nal step, if you cannot locate your dealer, please contact
customer service at Port-A-Cool, LLC. Please include your name, address and ZIP code,
the model number and serial number of your evaporative cooler, date of installation,
and a description of your problem. Port-A-Cool, LLC, 709 Southview Circle, Center, TX
75935, Tel: 1-800-695-2942, 936-598-5651. For more information or to register online,
visit www.kuulaire.com.
6. Cooling Pad / Cover
7. Drain Plug
5. Side Water Fill

Summary of content (2 pages)