User's Guide

The mechanical enclosure for the transceiver Module has an RJ45 for Gigabit Ethernet
network connectivity and PoE power input (802.3at, 802.3at+, or 802.3bt).
6 System Throughput
The K60c system uses time division duplexing (TDD) access mode, employing a single
frequency for both transmit and receive paths. The throughput for the downlink and uplink
depends on a downlink-to-uplink frame bandwidth ratio. The ratio is automatically
adjusted based on the offered load in each direction, taking into account all Remotes
connected to a Hub in PtMP. Furthermore, the system’s throughput depends on the
Modulation and Coding Rate (MCS) which varies according to link and signal conditions. The
following table details Ethernet uplink and downlink combined throughput for a K60c link.
Table 8: Throughput Performance for Cyclic Prefix of 1/8
7 Element and Network Management
The K60c system supports the following network management interfaces:
Kwikbit K60c User Guide - 14 -
K60c User Guide
Modulation
NCBPS
Repetitions
Code Rate
Data Rate
(Mbit/s)
π/2 BPSK
1
2
1/2
310
π/2 BPSK
1
1
1/2
620
π/2 BPSK
1
1
5/8
775
π/2 BPSK
1
1
3/4
930
π/2 BPSK
1
1
13/16
1007
π/2 QPSK
2
1
1/2
1240
π/2 QPSK
2
1
5/8
1550
π/2 QPSK
2
1
3/4
1860