5 System Installation
5.1 Wiring Diagram
To power the device, there are three options:
1.) An external DC power supply via the connector X1 can be used
2.) A PoE (802.11af) can be provided via X2
3.) or both interfaces can be used to power the device to have a redundant power supply.
For data communication there are two interfaces. A RS-485 interface on connector X1 and an
Ethernet interface on connector X2 (see Figure 11).
Only one data interface should be used at a time.
All possible communication, if configured properly, and power options are supported by the
sensor.
If other interfaces/protocols like Profinet, Profibus, Ethernet/IP, ModBus, digital I/Os or similar
are needed, an accessory from the KY-XTRA B family is necessary (for more details please
visit www.kymati.com).