The device confirms the reception of each file segment with an ACK Status Message.
In case of an error in any of the steps, a NACK Status Message is sent from the device along
with an optional Text message describing the error.
The new firmware will become active during the next reboot of the device.
Improper use of these messages may render the KYMATI Radar unusable.
Communication Setup (ContentType = 0x102)
This message can be used to (re-) configure the communication settings.
For Ethernet communication, send this message either to the local broadcast address of the
current subnet or to the universal broadcast address (255.255.255.255) on Port 27513.
Set the Source Routing Identifier to the communication port you are using, e.g. “Ethernet” or
Please use “Broadcast (0xFF) for the Destination Bus Identifier.
Field
Offset
Datatype
Description
Product ID
8
8
Array of
Characters (8 Bit)
Device specific
see: Radar Label
Serial Number
16
8
Array of
Characters (8 Bit)
Device specific
see: Radar Label
New RS-485
Bus Identifier
24
1
Unsigned Integer
(8 Bit)
Any value except
0 or 0xFF
reserved
25
1
reserved
26
1
reserved
27
1
New Device IP
Address
28
4
Unsigned Integer
(32 Bit)
e.g
“192.168.78.200
is 0xC0A84EC8
New Device
Netmask
Address
32
4
Unsigned Integer
(32 Bit)
e.g.
“255.255.255.0”
is 0xFFFFFF00
New Device
Gateway
Address
36
4
Unsigned Integer
(32 Bit)
e.g.
“192.168.78.1” is
0xC0A84E01
New
Destination IP
Address
40
4
Unsigned Integer
(32 Bit)
e.g.
“192.168.78.1” is
0xC0A84E01
New
Destination
Port
44
2
Unsigned Integer
(16 Bit)
Default:
27513
After reception and validation of this message, the device will change the internal parameters