User Guide

9. DRIVE AND DRIVEN PULLEYS/
KICK STARTER
9-10
Pull out the guide roller pins and guide rollers.
Remove the movable driven face from the
driven face.
Remove the oil seal from the movable driven
face.
INSPECTION
Measure the driven face spring free length.
Service Limit: 163.7mm replace if below
Check the driven face for wear or damage.
Measure the driven face O.D.
Service Limit: 33.94mm replace if below
Movable Driven Face
Guide Roller Pin
O-ring
Guide Roller
Oil Seal