Operation Manual

10-10
Troubleshooting > Troubleshooting
Printouts are fuzzy. Is the machine being used in conditions
of very humid, or humidity or
temperature rapidly changes?
Use in an environment that has suitable
humidity.
Select the [
Menu
] key > [
Adjust/Maint.
]
> [
Service Setting
] > [
Drum
], and then
select [
Yes
].
ECOSYS P7040cdn: Select the [
Menu
]
key > [
Adjust/Maint.
] > [
Service
Setting
] > [
Drum Heater
], and then
select [
On
].
NOTE
This function cannot be turned on in
some regions.
Images are skewed. Is the paper loaded correctly? Check the position of the paper width
guides.
page 3-4
Irregular horizontal lines
appear in the image.
ECOSYS P6035cdn: Select the [
Menu
]
key > [
Adjust/Maint.
] > [
Service
Setting
] > [
MC
] and increase the
adjustment value. Increase the
adjustment value 1 level at a time from
the current value. If there is no
improvement after the value is
increased by 1 level, increase by 1 level
again. If there is still no improvement,
return the setting to the original value.
The altitude is 1000 m or
higher and irregular
horizontal white lines appear
in the image.
Select the [
Menu
] key > [
Adjust/Maint.
]
> [
Service Setting
] > [
Altitude Adj.
],
and set to an elevation one level higher
than the current setting.
The altitude is 1000 m or
higher and dots appear in
the image.
Select the [
Menu
] key > [
Adjust/Maint.
]
> [
Service Setting
] > [
Altitude Adj.
],
and set to an elevation one level higher
than the current setting.
Symptom Checkpoints Corrective Actions
Reference
Page