Instruction Manual

66
2. Measurement Category
W ARNIN G
n
Measurement Category (CAT.)
The restrictions on the maximum voltage level for which the KEW1061, KEW1062 can
beused,dependonthemeasurementcategoriesspeciedbythesafetystandards.
Do not apply any input level higher than maximum allowable input.
AC/DC 1000V CAT. III
AC/DC 600V CAT.
Measurement
category
Description Remarks
CAT. I For measurements performed on circuits not
directly connected to MAINS.
CAT. II For measurements performed on circuits directly
connected to the low voltage installation.
Appliances, portable
equipment, ect.
CAT.III For measurements performed in the building
installation.
Distribution board,
circuit breaker, ect.
CAT.
For measurements performed all the source of the
low-voltage installation.
Overhead wire,
cable systems, ect.
Internal Wiring
Outlet
Entrance
Cable
Fixed Equipment,
etc.
Distribution
Board
CAT. II
Equipment
C A T.I
CAT.IV
CAT. III
Note
Radiation immunity affects the accuracy of the KEW1061, KEW1062 under the
conditionsspeciedinIEC61326-1.
Useofthisinstrumentislimitedtodomestic,commercial,andlightindustry
applications. If equipment generating strong electromagnetic interference is located
nearly, the instrument may malfunction.