Owner manual

―15―
Set the function selector switch to the "A" position. AC" should
be shown on the upper left corner of the display.
Press the trigger to open the transformer jaws and clamp them onto
a single conductor and take the reading on the display. The most
accurate reading will be obtained by keeping the conductor at the
center of the transformer jaws.
NOTE
During current measurement, keep the transformer jaws fully
closed. Otherwise, accurate measurements cannot be taken.
Maximum conductor size is 55in diameter.
Zero adjustment is not necessary in AC current measurement.
When the current under test measures 3% of the full scale or less,
or the frequency of the current is low, "LoHz" is indicated on the
display.
6−3 DC Voltage Measurement
DANGER
Never use the instrument on a circuit above 1000VDC. This may
cause electrical shock hazard and damage to the instrument or the
circuit under test.
Do not make measurement with the battery compartment cover
removed.
Keep your fingers and hands behind the barrier during measurement.