User guide

̶
10
̶
●Operating System ΔΣ modulation
●Display Liquid crystal display with a maximum
count of 4200 plus annunciators
●Overrange Indication "OL" is shown on the display
●Response Time Approx. 2 seconds.
●Sample Rate About 3 times per second.
●Location for use Indoor use, Altitude up to 2000m
●Temperature and Humidity
23 +/-5℃ , relative humidity up to 75%
 for Guranteed Accuracy without condensation
●Operating Temperature 0-40℃ , relative humidity up to 85%
 and Humidity without condensation
●Storage Temperature -20-60℃ , relative humidity up to 85%
 and Humidity without condensation
●Power Source Two 1.5VDC R6P (SUM-3) batteries
●Current Consumption Approx. 40mA max (ACA).
●Auto-power-off function Automatically powered down in about
10 minutes after the last switch
operation
(power consumption: about 200μA)
●Overload Protection DC/AC current ranges:
  2400A AC for 10sec
DC/AC voltage ranges:
  1200V AC/DC for 10sec
Resistance range:
  1000V AC/DC for 10sec
●Withstand Voltage 6880V AC, 50/60Hz for 5 seconds
between electrical circuit and housing
case or metal part of the jaws
●Insulation Resistance 10MΩ or greater at 1000V between
electrical circuit and housing case or
metal part of the jaws
●Conductor Size Approx. 55㎜ diameter max.
●Dimensions 250(L)x105(W)x49(D)mm
●Weight About 540g
●Accessories Test leads M-7017
R6P battery
Carrying case M-9094
Instruction manual
Recorder output Plug M-8201
●Optional Accessories Multi-Tran M-8008
Output Lead M-7014.