User guide

̶
22
̶
DANGER
●Never use the instrument on a circuit above 750VAC/1000VDC.
This may cause electrical shock hazard and damage to the
instrument or the circuit under test.
Do not make measurement with the battery compartment cover
removed.
Do not make measurement with the test leads plugged into the
instrument.
Keep your fingers and hands behind the barrier during
measurement.
 ① The PEAK mode is available on DCA, ACA, DCV and ACV
ranges.
  Set the function selector switch to the desired position.
Note: Only on DCA range, press the Zero Adjust/Reset button
for about one second to zero adjust the reading with the
transformer jaws closed.
 ②
Press the mode selector button twice to enter from the normal
mode to the PEAK mode. "PEAK" should be shown on the display.
 ③Follow instructions for DCA, ACA, DCV or ACV measurement.
Note: For accurate reading, press the Zero Adjust/Reset button to
reset the reading after clamping onto the conductor or making
test lead connections to the circuit under test. Then, proceed
to measurement.
Peak Hold
INPUT Current