Manual

̶
19
̶
7.3.3 Contents displayed on Sub Display
LOOP test results are displayed as illustrated below.Results
displayed on the LCD are dependent on the selected function.
Pressthe“DISP”Switchtotogglethetestresultsdisplayedonthe
SubDisplay.
Fig.7-7
ContentsdisplayedonSubDisplay
Function
(A)
Contents
displayed on Sub
Displayaftertests
(B) (C)
L-PE
ATT ON
PFCValue
L-NLOOP
Value
PSCValue
Back to (A)
L-PE
ATT OFF
PFCValue
Push
L-NLOOP
Value
Push
PSCValue
Push
Back to (A)
L-N/L-L PSCValue
L-NorL-L
Voltage
Back to (A)
●If the display shows '>' then this usually means the value
measured exceeds the range.
●MeasurementinL-PEATTONfunctionrequireslongertimethan
that is required for the other measurements (approx. 7 sec).
Whenmeasuringacircuitwithalargeelectricalnoise,the'Noise'
MessageisdisplayedontheLCDandthemeasurementtimewill
beextendedto20sec.Ifthe'NOISE'symbolisdisplayedonthe
LCD,itisrecommendedtomakemeasurementinL-PEATTOFF
function.(RCDsmaytrip).
●Ifanimpedanceof20ΩormoreismeasuredbetweenL-Nduring
measurements in L-PEATT ON function,L-N>20Ω”is displayed
on the LCD and no measurement can be made. In this case,
select L-PEATT OFF function and make measurement. RCD
maytripwhenperformingatestatL-PEATTOFFfunction.
●
Whena largecontact voltageexists inthecircuit undertest,“n-E
Hv”isdisplayedontheLCDandnomeasurementcanbemade.In
thiscase,selectL-PEATTOFFfunctionandmakemeasurement.
RCDmaytripwhenperformingatestatL-PEATTOFFfunction.
●Ifthesymbol( )appears, this means that the test resistor is too
hot and the automatic cut out circuits have operated. Allow the
instrument to cool down before proceeding. The overheat circuits
protect the test resistor against heat damage.