43 Continuity testing
1Press the test button once. Then, the instrument switches on.
2Select the continuity test by rotating the function dial.
3Connect the test leads to the circuit whose resistance is requiredsee Fig
3)HAVING FIRST MADE SURE THAT THE CIRCUIT IS NOT LIVE.
Note that the live circuit warning lamp will illuminate if the circuit is live
-
but
check first anyway!
4Press the test button and read the circuit resistance from the display.
5Note that if the circuit resistance is greater than 20 Ω the instrument will
autorange to the 200 Ω range.
6Subtract the test lead resistancemeasured in 4.2 abovefrom the
display reading.
7The result will be the resistance of the circuit under test.
NoteIf the reading is greater than 200Ω the over range symbol "OL" will
remain displayed.
The results of measurements can be adversely affected by impedances
of additional operating circuits connected in parallel or by transient
currents.
Fig 3
TEMPORARY
LINK
test at socket
between L and E
L
N
E