Owner's manual

̶
9
̶
 
4. SPECIFICATION
Measurement Specification
Function Range
Rated Voltage
(AC)
Test
Current
Accuracy
LOOP
PSC
Function
Uc
20Ω
L-PE :
+
10%
230V 50Hz
-15%
3A
15mA
15mA
15mA
3A
max15mA
5mA only at
I⊿n=10mA
± (3%rdg+8dgt)
± (3%rdg+8dgt)
At L-L measurement:
± (3%rdg+12dgt)
± (3%rdg+8dgt)
PSC accuracy is a
derived from
measured loop
impedance
specification.
200Ω
2000Ω
200A
2000A
20kA
L-PE :
+
10%
230V 50Hz
-15%
L-L :
+
10%
400V 50Hz
-15%
L-PE :
+
10%
230V 50Hz
-15%
L-L :
+
10%
400V 50Hz
-15%
L-PE :
+
10%
230V 50Hz
-15%
Range
100V
Rated Voltage
(AC)
L-PE :
+
10%
230V 50Hz
-15%
Test
Current
Accuracy
+5%∼+15%
± 8dgt