Quick Manual Instruction Manual

27
KEW6305
KEW6305
Wiring check:
WIRING CHECK
Range
10. Wiring check:
WIRING CHECK Range
10-1Checking procedure
Select the WIRING CHECK Range for checking proper connection.
STEP1
After connections are complete, set the Function switch to the
WIRING CHECK
Range.
Then present voltage, current, power factor and electric power (instantaneous value) are
displayed on the LCD as shown in the table below.
STEP2
Press the Key.
symbol keeps
blinking for about 5 sec.
STEP3
Check result will be
displayed as follows.
Everything is OK. Error is found.
* Check results may be affected if great power factors (0.5 or less) exist at the measurement sites.
Wiring system
(Setting no. 01)
Display
position
Items to be displayed
Screen
1
Screen
2
Screen
3
Screen
4
Screen
5
Screen
6
3P4W
3P3W3A
Top
Middle
Bottom
f
V(avg)
A(avg)
V1
V2
V3
A1
A2
A3
P1
P2
P3
PF1
PF2
PF3
DEG(V1)
DEG(V2)
DEG(V3)
3P3W
1P3W
Top
Middle
Bottom
f
V(avg)
A(avg)
V1
V2
A1
A2
P1
P2
PF1
PF2
DEG(V1)
DEG(V2)
1P2W (3ch)
Top
Middle
Bottom
f
V
A(avg)
V
A1
A2
A3
P1
P2
P3
PF1
PF2
PF3
1P2W (2ch)
Top
Middle
Bottom
f
V
A(avg)
V
A1
A2
P1
P2
PF1
PF2
1P2W (1ch)
Top
Mid
dle
Bottom
f
V
A1
V
A1
P1
PF1