User Manual
KEW6310 6.4.2 Instantaneous value measurement -Over-range / Bar indication
KEW6310 6.22
Bar Indication
The calculations and measurements performed by this instrument are based on the voltage and frequency
of V1. If the value of V1 is less than 5% of the chosen range or if the fre quen cy is not w ithin 40 ~ 70Hz, al l
the parameters (except for voltage and current ) cannot be computed and thus displayed. In such a case,
the numeric al digits will be replaced by a bar indication (“- - - -”) as shown:
Zero Indication
Zero “0” is display ed w hen me asured i tems e xcee ds fo llow ing condi tions.
Volt age : V ol t age Range x VT ra tio x 5% e.g. Voltage R ange : 300V, VT ratio : 1 => 15V
Current : Current Range x CT ratio x 1% e.g. Current Range : 200A, CT ratio : 2 => 4A
“-------“ is displayed.
0 is displayed.