User's Manual

8
6. Setting - Indicator
Danger / Caution Area Distance Setting
Setting Initialization
Volume Control
Press and hold SET
1 and SET 2 buttons
simultaneously for 2
seconds or more.
When the green LED is
on, set the distance to the
Caution Area
.
① Press and hold the STOP button for more than 2 seconds.
When the red LED is flashing sequentially, press and hold the STOP button again for more
than 2 seconds. The LED will turn off and the setting will be initialized. Reboot will take
about 5 seconds.(Do not turn off the vehicle until the green LED flashes.)
※ Default values after initialization : 4m for Danger Area / 8m for Caution Area
SET 1 Button : - Volume SET 2 Button : + Volume
Set the desired
Danger
Area
distance by operating
the SET 1 and SET 2
buttons. (Refer to "How
to set the distance" on the
following page)
Set the desired
Caution
Area
distance by operating
the SET 1 and SET 2
buttons. (Refer to "How to
set the distance" on the
following page)
Press STOP to complete
the
Danger Area
setting.
Press STOP to complete
the
Caution Area
setting.
In a condition of normal operation
In a condition of normal operation
※ In case of malfunction