Install Manual Part 3

SKY497
Installation Manual
B-3
Rev. C
Figure B-2. Start-up Screen
After approximately thirty seconds the display will show the STANDBY screen (see figure B-3).
NOTE
If the TRC has not been calibrated to the directional antenna (see step 6
below), the display may show a “SKY497 FAILED” message.
Figure B-3. Standby Screen
5. Turn SKY497 OFF and then enter the Service Menu (see paragraph 4.4) by holding the left two
buttons (soft-keys 1 and 2) depressed as the system is turned ON.
6. From the Service Menu, calibrate the TRC to the directional antenna (see paragraph 4.4.1).
7. Return to the Service Menu and select System Data (see paragraph 4.4.3).
a. Verify status and save the configuration jumpers (see paragraph 4.4.3.2, Configuration).
b. Verify that the system has recognized and is responding to installed sensors (see paragraph
4.4.3.3, Data Monitor).
1) Sequence through each Data Monitor display page.
2) Verify that the sensor information displayed is correct.
3) If the information is not correct, the sensor has failed to communicate with the TRC.
Check operation of the sensor and cables between the TRC and sensor.