User guide

3. If the flame in your torch becomes extinguished,
shut off the gas immediately and wait until you
are certain the gas has cleared away before
relighting. Torches equipped with a safety
control valve and thermo-couple assembly are
designed to automatically shut off the gas supply
if the flame is extinguished.
4. Constant supervision of the torch is required
when in operation.
5. Ensure the torch receives the proper operating
pressure as given in the specification table for
the specific torch. See pages 5 - 8. Do not
operate torch above prescribed operating
pressure. Excess pressure may cause blowout
of flame resulting in explosion with death or
serious bodily injury.
6. Do not direct flame toward the gas cylinder as
heat causes increased pressure. The safety
valves on the cylinder may open releasing gas
into the air, which can explode if ignited by the
torch flame.
7. Keep the torch and its exposed flame away from
all combustible materials (paper, cardboard,
building materials, etc.)
8. Keep temperature of all gas cylinders below 100°
F. Keep all cylinders out of enclosed areas.
9. Some torch models require a regulator to be
connected to the gas supply to provide proper
operating pressure. Other torches operate with
direct tank pressure. Refer to the following table
to determine if your torch requires a regulator for
operation.
10. Use of an incorrect hose, regulator, POL fitting,
or excess flow valve may lead to gas leaks and
explosion or asphyxiation. If the torch is
purchased without these items, or if these items
are lost or damaged, contact the L. B. White Co.
to obtain information on the correct parts to use
with each torch.
11. Incorrect assembly of torch can result in fire,
explosion, death, or bodily injury from
asphyxiation due to gas leaks.
12. Follow assembly and operating instructions in
owner's manual supplied with each torch, before
using torch. If an owner's manual is lost or not
available, contact L. B. White to obtain a copy on
the correct parts to use with each torch.
13. If you suspect a gas leak or smell gas odor,
EXTINGUISH ALL FLAMES AND SPARKS
IMMEDIATELY. CALL YOUR LP GAS DEALER
AND YOU FIRE DEPARTMENT.
14. LP gas is heavier than air and settles in low
areas. Do not install LP gas burning equipment
in an area where gas may settle.
15. Inspect the torch at time of installation, and at
each start up for gas leaks and at least once a
month and whenever accidental damage occurs.
Any damage to the torch must be repaired
immediately by a qualified service person.
16. If the torch is not working properly, remove from
service immediately. Have it repaired and tested
by an authorized person before placing it back
into service.
17. Use gas pipe joint compound that is resistant to
LP gas and natural gas on all connections.
18. Use only L. B. White replacement parts on our
torches.
19. This torch is not to be used in heating living
quarters.
20. The hose assembly shall be visually inspected
prior to each use of the torch. If it is evident
there is excessive abrasion or wear, or if the hose
is cut, it must be replaced prior to the torch being
put into operation. The hose assembly shall be
protected from traffic, building materials and
contact with hot surfaces during use and while in
storage. The replacement hose shall be that
specified by the manufacturer. (See parts list for
specific torch.)
3
WARNING
Do not use a pressure washer, water, or liquid
cleaning solution on any safety control
components. Use of a pressure washer, water, or
liquid cleaning solution on the safety control
components can cause severe personal injury or
property damage due to water and/or liquids:
* Causing corrosion which can result in gas
leaks and fire or explosion from the leak.
Clean all components of the torch with a dry brush
or dry cloth.
Torch Regulator Regulator
Model Required Not Required
156 X
162 X
163 X
164 X
166 X
168 X
169 X
171 X