User Manual

Marine Systems
Aviation Recorders
Rev. 06
Mar . 16/11
165M0014-10
Page 3--5
For steps (5) through (9) refer to Paragraph 3.1.2.
(5) Connect the IEC cable to data port on back of Transponder.
NOTE
: If an interface adapter must be used to convert either Gyro
output and/or dGPS output to IEC (NMEA 0183) standard,
the output from the interfaces should be located as near as
possible to t he sending unit (Gyro or dGPS) and the output
cables led to the IEC terminal block.
(6) Lead data cables from Gyrocompass data output port to terminal block.
(7) Lead data cables from ship’s DGPS data output port to terminal block.
(8) Feed the IEC data cable to the terminal block.
NOTE
: The metallic shielding of each of the three shielded cables
containing the twisted pairs must be connected to the
terminal block using the shield drain wire connected to the
shield. The shields from Cables 1 and 2 do not have to be
connected. The shield from Cable 3 must be connected to
TB pin ID 30, which is grounded to the ship’s hull.
(9) Connect each wire in the IEC data cable to the terminal block. (Refer to
NO TAG and NO TAG.)
(10) Connect power cable to transponder. (Refer to Figure 3 --7.)
(11) Connect power cable to ships 24Vdc, 10A minimum power supply is recom-
mended. ( Red + , Black -- )