Gas and Electrical Requirements
26
INSTALLATION
Check the appliance is electrically safe when you have nished.
4-Wire Conduit Installation
Disconnect the supplied power cord from the terminal block 
and ground post. Keep the terminal block parts; you will need 
them. Remove the strain relief clamp from the power cord 
and remove the power cord and strain relief clamp from the 
mounting bracket (Fig. 6-3).
The range is shipped with reducer plates to give a 1
1
/
8
’’  
(2.9 cm) diameter opening for conduit connection. Find the 
reducer plates (Fig. 6-4) in the conversion kit and x them to 
the mounting bracket.
Attach a squeeze connector (not supplied with the range) to 
your conduit. Insert the conduit through the reducer plates 
on the mounting bracket. Allow enough slack to easily attach 
the wires to the terminal block.
Note: Do not install the conduit without a squeeze connector.
Attach the wires to the ground post and terminal block (Fig. 
6-5).
Note: Make sure the wires are completely inserted into the 
terminals and secure connections are made.
Secure the squeeze connector in place in the bracket by 
tightening the squeeze connector screws.
Replace the electrical connection cover.
Installing a 3-Wire Power Cord
Disconnect the supplied power cord from the terminal block 
and ground post. Keep the terminal block parts; you will need 
them. Remove the strain relief clamp from the power cord 
and remove the power cord and strain relief clamp from the 
mounting bracket. Discard the strain relief clamp.
Note: Do not install the power cord without a strain relief – 
use the clamp supplied with the cord.
Install the new strain relief device to the mounting bracket by 
removing the two clamping screws, feeding the two halves 
(ears rst) through the hole in the mounting bracket and 
loosely replacing the screws. Insert the power cord through 
the strain relief device but do not tighten the device yet (Fig. 
6-6).
A ground strap is supplied in the conversion pack (Fig. 6-7).
Attach the ground strap to the ground and center terminal of 
the connector block (Fig. 6-8).
The neutral or ground wire of the power cord must be 
connected to the neutral terminal located in the center of the 
connector block. The power leads must be connected to the 
outside terminals.
Make sure the connections are tight. Now tighten the strain 
relief device to clamp the power cord.
Ret the electrical connection cover.
ArtNo.280-0041 - Strain relief bracket 3-wire
ArtNo.280-0040 4 Wire Conduit Fitting
Red
White
Green
Black
ArtNo.280-0039 Reducer Plate
ArtNo.280-0081 - 4 Wire 
conduit terminal connection
Black
White
Red
Green
Ground
ArtNo.280-0082 - 3-Wire conduit connection
Strain relief
device
White
Black
Red
‘Ground strap’
Ground
ArtNo.280-0042 Ground Strap