Quick Start Guide
12 13Quick Start GuideCRC-VEU-WH / CRC-VEU-BK
Wiring and Installation
Wire the CRC-VEU to any Remote port on a CA, CM, CMA and CPA product to control the volume of the channel
associated with the Remote port. With custom cabling, a single remote can also be paralleled to the other
channels remote port on a two-channel device.
RJ-45 Pin Color Potentiometer Description
1 White / orange Fixed end VCC 10 V
2 Orange Variable / wiper Volume control
8 Brown Fixed end Ground
Operation
The CRC-VEU volume control is Attenuation only,
i.e., the volume control can only be used to reduce
the volume. The CRC-VEU remote volume control
and the amplier’s master volume control are in
series and both always active.
Typical conguration includes the following steps:
1. Turn the CRC-VEU volume knob to maximum
(fully clockwise).
2. Adjust the amplier’s master volume control
to the loudest setting you expect will ever
beneeded.
3. Turn the CRC-VEU volume knob down to the
desired listening level.
By following this conguration method, the
listening level set by the CRC-VEU remote volume
control can never exceed the maximum level set on
the amplier’s master volume.
Dimensions
80,01
[3.1500]
80,01
[3.1500]
41
[1.6]
60,40
[2.3780]
22,83
[0.8989]
60,40
[2.3780]