Overview
The unit shall incorporate two core elements: a four-in/four-out
digital loudspeaker drive processor and a four-channel, high-output
power amplifier platform. Additional facilities shall include on-board
surveillance and load monitoring capability; Ethernet-based audio
networking and control; third-party control system compatibility
using custom middleware; and comprehensive system configuration
and control using
a PC software interface supplied with the unit. The
included integrated software package also shall include a custom
amplifier configuration interface and additional features to expedite
system design, specification and commissioning.
Digital Loudspeaker Processing
Maximum total power output shall be 20,000 W or 5,000 W per
channel nominal @ 2.67 ohms; output at 4 ohms shall be 4400 W
per channel nominal. Maximum output into a 100 V high-impedance
distributed system shall be 4700 W. The amplifier topology shall
allow exibility in output power management, with the capability to
allocate total available power across output channels as needed for
the application. Maximum peak output vol
tage shall be 194 V and
maximum output current shall be 67 A. The amplifier shall incorporate
power factor correction (PFC) to reduce requirements on the mains
distribution system. Amplifier gain shall be digitally configurable from
22 dB to 44 dB. The unit shall exhibit the following performance
parameters: Frequency response shall be 20 Hz – 20 kHz ± 0.05 dB
(1 W into 8 ohms). Dynamic range shall be >114 dB. Pro
pagation
delay shall not exceed 1.61 ms for AES3 input (96 kHz) or 1.68 ms
for analog input. The unit shall incorporate a DSP-implemented zero
overshoot voltage peak limiter adjustable per channel for voltage
threshold and profile.
The unit shall include facilities for status surveillance and load
monitoring consistent with international standards for use in mission-
critical voice evacuation systems. Circuits and sensors shall be
provided for warning and protection of VHF (very high frequencies),
DC at output, over-temperature, open load, excessive current, and
voltage peak clipping.
Connectors and User Interfaces
Power Supply, Protection and Coolin
g
The power supply shall be a universal regulated, switch-mode type
operating at voltages from 70 265 V AC at 45 66 Hz. A soft-
start circuit shall limit current inrush to 8 A. A software congurable
breaker emulation limiter shall safeguard against tripping of AC
mains breakers. The unit shall be cooled by temperature-controlled
fans with air flow from front to rear.
Physical
The unit shall be 483 mm (19 in.) wide, 8
8 mm (3.5 in. /2U) high, and
424 mm (16 in.) deep. Weight shall be 16.5 kg (36 lbs). Finish shall
be black painted steel with grey painted steel front and detachable
grille. The unit shall be approved for use as specified by CE, ETL
(ANSI/UL, CSA), PSE and RCM.
The unit shall be the Lab.gruppen D 200:4L.
D SERIES 200:4L
Architects’ and Engineers’ Specification
D SERIES LAKE: High-Power Installation Platform
The unit shall include four discrete modules of digital loudspeaker
processing. Audio inputs shall be analog with oating ground
isolation, AES3 digital, AES67 and dual redundant Dante
Ethernet-based network. Auto failover switching among inputs
shall be user programmable. Facilities shall be provided for
exible input mixing and routing. DSP capabilities shall include
raised cosine equalization, linear-phase and classical crossovers,
and peak and RMS limiters.
The rear panel shall provide two EtherCon connectors for AES67
and Dual Redundant Dante Ethernet-based audio and for
bi-directional monitoring and control data with third-party support.
Four three-pole terminal block connectors shall be provided for
analog audio inputs and two three-pole terminal block connectors
for AES3 digital inputs. Output connectors shall be on terminal
block connectors with supplied mating connectors accepting cable
up to 16 mm2 (6 AWG). The front-panel user interface shall provide
tri-color indicator LEDs for FRAME status, TEMPerature and PSU
status; and four channel status indicators (LOAD, AMP, SIGNAL,
MUTE). A soft-touch POWER button shall select ON or STANDBY
mode with LED status indication. A soft-touch SELECT button with
LED status indicator shall select software functionality.