A & E Specifications

WWW.LABGRUPPEN.COM
Item no. AES-DSERIES804T/Ta_V2 - 27.05.2015
Overview
The unit shall incorporate two core elements: an AVB-capable
network interface for control, monitoring and four-channel audio
compatible with the Tesira
®
protocols from Biamp Systems; and
a four-channel high-output power amplifier platform. Additional
capabilities shall include on-board surveillance and monitoring of
critical performance parameters for compliance with international
standards for voice evacuation systems. All control and monitoring
facilities shall be accessible via Ethernet using an integrated
software package that includes Tesira
®
software, a custom amplifier
configuration interface, and additional features to expedite system
design, specification and commissioning.
Tesira
®
Network Integration
The unit shall integrate seamlessly into the Tesira
®
audio networking,
control and DSP environment as a high-powered expander device.
The unit’s mute, level and signal invert functions, along with load
surveillance, shall be accessible from within the Tesira
®
software.
Four channels of audio input shall be provided via Tesira
®
using the
AVB networking protocol. An optional analog input section shall
provide analog failover as well local input to the Tesira
®
system.
The unit’s power state management (including auto power-down),
GPIO and serial port functions also shall be integrated into the
system. Replacement units shall be hot-swappable within the Tesira
environment with full configuration transfer.
Power Amplier
Maximum total power output (all channels driven) shall be 8,000 W
or 2,000 W per channel nominal at 4 ohms. Maximum output into
a 100 V high-impedance distributed system also shall be 2000 W.
Maximum peak output voltage shall be 194 V and maximum output
current shall be 67 A. The amplifier topology shall allow flexibility
in output power management, with the capability to allocate total
available power across output channels as needed for the application.
The amplifier shall incorporate power factor correction (PFC) to
reduce requirements on the mains distribution system. Amplifier
gain shall be digitally configurable from 22 dB to 44 dB. The unit shall
exhibit the following performance parameters: Frequency response
shall be 20 Hz – 20 kHz ± 0.05 dB (1 W into 8 ohms). Dynamic
range shall be >114 dB. Propagation delay (server analog input to
output) shall not exceed 3.857 ms. The unit shall incorporate a DSP-
implemented zero overshoot voltage peak limiter adjustable per
channel for voltage threshold and profile. The optional four-channel
analog input section shall offer balanced mic/line inputs with 48 V
phantom power and 24-bit/48 kHz A-D converters.
Load Verication and Circuit Protection
The unit shall include facilities for status surveillance and load
monitoring consistent with international standards for use in mission-
critical voice evacuation systems. Circuits and sensors shall be
provided for warning and protection of VHF (very high frequencies),
DC at output, over-temperature, open load, excessive current, and
voltage peak clipping.
Connectors and User Interfaces
The rear panel shall provide an Ethernet AVB port (RJ45 connector)
for bi-directional audio, control and monitoring data. Optional analog
mic/line inputs shall use 3-pole terminal block connectors. A serial
control port (DB9 connector) shall facilitate power management,
and a GPIO port shall be accessed via a terminal block connector.
Output connectors shall be on terminal block connectors with
supplied mating connectors accepting cable up to 16 mm
2
(6 AWG).
The front-panel user interface shall provide three tri-color LEDs for
system status indication (ALARM, ACTIVITY and STATUS); and
three channel status indicators (LOAD, AMP, SIGNAL). A soft-touch
POWER button shall select ON or STANDBY mode with LED status
indication. A soft-touch SELECT button with LED status indicator
shall select software functionality.
Power Supply, Protection and Cooling
The power supply shall be a universal regulated, switch-mode type
operating at voltages from 70 – 265 V AC at 45 – 66 Hz. A soft-
start circuit shall limit current inrush to 8 A. A software configurable
breaker emulation limiter shall safeguard against tripping of AC
mains breakers. The unit shall be cooled by temperature-controlled
fans with air flow from front to rear.
Physical
The unit shall be 483 mm (19 in.) wide, 88 mm (3.5 in. /2U) high, and
424 mm (16 in.) deep. Weight shall be 14.5 kg (3 lbs). Finish shall
be black painted steel with grey painted steel front and detachable
grille. The unit shall be approved for use as specified by CE, ETL
(ANSI/UL, CSA), PSE and RCM.
The unit shall be the Lab.gruppen D 80:4T with AVB input only;
the Lab.gruppen D 80:4Ta with optional analog inputs.
D SERIES 80:4T/Ta
Architects’ and Engineers’ Specification
D SERIES TESIRA®: High-Power Installation Platform