Tesira Operation Manual
9. Front panel interface
D SERIES Tesira Operation Manual rev 1.0.0
17
9.3. Frame select and ID
9
SELECT LED and TOUCH BUTTON – Selects mode and indicates control between computer software and
unit. A single touch on the button will select the unit in supported computer software views. In the other direction,
when selecting the unit in a supported computer software view, the LED will indicate the unit is selected by
illuminating.
NOTE: The touch buttons use capacitive touch technology and might be sensitive to large temperature
and humidity variations.
OFF Green Amber Red
Alarm
Device OK N/A
Frame warning/Minor
Tesira fault active
Frame fault/Major
Tesira fault active
Activity
N/A
Device active in an active
system
N/A
Device is part of an inactive
system (audio stopped)
Status
N/A
Device congured and ready
to participate in a system
Device is ready and waiting to
receive a conguration
Device is not ready to receive
a conguration
Power
Mains power not available Device is ON Device in STANDBY Device in SLEEP
Load
Frame/Amp fault active Load OK Load warning active Load fault active
Amp
Frame fault active Amplier channel OK
Amplier channel
warning active
Amplier channel
fault active
Signal
Input signal below present
threshold or Frame/Amp
fault active
Signal above signal
present threshold
N/A Signal clip or limit/fault active
Mute
N/A Not muted N/A Muted
Select
Device not selected Device selected N/A N/A
Table 9.1: LED/category chart










