Rev. 1.2.0 Item no.
1. Important safety instructions 1. Important safety instructions Before using the device, be sure to carefully read the Safety Instructions. Keep this document with the device at all times. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 2 Read these instructions. Keep these instructions Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Do not block any ventilation openings.
. Warnings To completely disconnect this equipment from the AC mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the power supply cord shall remain readily operable. Français: Pour démonter complètement l’équipement de l’alimentation générale, démonter le câble d’alimentation de son réceptacle. La prise d’alimentation restera aisément fonctionnelle. To reduce risk of fire or electric shock, do not expose this apparatus to rain or moisture.
. Table of Contents 4. Table of Contents 1. Important safety instructions 2 2. Approvals 2 3. Warnings 2 3.1. Explanation of warning symbols 2 3.2. Warnings 2 3.3. Caution 3 3.4. User responsibility 3 3.4.1. Mains connection grounding 3 3.4.2. Speaker output hazard on amplifiers 3 3.4.3. Radio interference 3 3.4.4. Speaker damage 3 3.4.5. Maintenance 3 5. Introduction 6 5.1. Welcome 6 5.2. D Series: Two versions available 6 6. Feature summary 6.1.
4. Table of Contents 8. Cooling and fan operation 10 9. Operating voltage 10 9.1. Low voltage country considerations 10 10. Grounding 11 11. Product overview 12 11.1. Front panel 12 11.2. Rear panel 14 12. Signal flow and processing 15 13. Quick Start Tutorial 16 13.1. Software installation and firmware update 16 13.1.1. Tesira Software 16 13.1.2. Firmware update 16 13.2. Network setup 17 13.3. System setup 18 13.4. Basic Configuration 20 14.
5. Introduction 5. Introduction 5.1. Welcome Thank you for choosing the Lab.gruppen D Series for your sound reinforcement needs. We are confident that you will be pleased with the performance, unique features, configuration flexibility, reliability, and long-term durability offered by this product. For fast installation and use of this product, your welcome package includes this printed copy of the D Series Quick Start Guide.
6. Feature summary 6.
7. Installation 7. Installation 7.1. Unpacking Carefully open the shipping carton and check for any damage to the device or the supplied accessories. Every Lab.gruppen product is tested and inspected before leaving the factory and should arrive in perfect condition. If any damage is discovered, please notify the shipping company immediately. Only the consignee may initiate a claim with the carrier or their insurers for damage incurred during shipping.
7. Installation Rear support bracket with mounting hardware Rear support bracket mounted for fixed installation and bracket pointing forward Rear support bracket mounted for removable installation and bracket pointing towards back 7.2.2. Mounting front grille The front grille is shipped on top of the amplifier inside the box to protect it during shipping. The front grille adheres to the amplifier with magnets.
8. Cooling and fan operation 8. Cooling and fan operation D Series devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or lids are placed at the front or rear of the rack. Never attempt to reverse the airflow.
10. Grounding Connecting the amplifier in three phase delta configuration In three-phase configuration where the phases are 120 degrees apart, one can connect three balanced loads in a delta configuration. The connection is made between the phases instead of between the neutral and a phase.
11. Product overview 11. Product overview 11.1. Front panel 1 The front panel is consists of an outer front with air intake and a centered user interface. The user interface has LEDs for monitoring and six recessed touch buttons for control.
11. Product overview Table 1 LED/category chart NOTE: See Faults and warnings (pages 21-22) for a detailed description of status, faults and warnings associated with each LED.
11. Product overview 11.2. Rear panel 1 2 3 4 6 5 ANALOG OPTION 1 Amplifier Outputs - The amplifier output connectors are sturdy terminal block connectors. See Technical Specifications (pages 23-24) for connector rating. Channels are located from left to right. Each channel has a clearly marked hot (+) and cold (-) terminal.
12. Signal flow and processing 12. Signal flow and processing The table below depicts the audio signal flow for a D Series Tesira device.
13. Quick Start Tutorial 13. Quick Start Tutorial This section will describe how to get started with associated software and set up a basic system for operation. 13.1. Software installation and firmware update 13.1.1. Tesira Software 1. Download Tesira Software from biamp.com: www.biamp.com/products/tesira/downloads.aspx. Locate the Software and Firmware section and download the latest version of Tesira software. 2. Execute the installer and follow the on-screen instructions.
13. Quick Start Tutorial CAFÉ software 1. Download the latest CAFÉ software from www.labgruppen.com 2. Execute the installer and follow the on-screen instructions. This is a typical software installation where the default settings are acceptable for the vast majority of users. 13.2. Network setup Network connections/topology The following diagram shows a typical setup with Tesira software running on a PC.
13. Quick Start Tutorial 13.3. System setup The setup guide describes how to get a simple system up and running, connect audio through to the amplifier, and make basic configurations of the amplifier. This guide assumes you have a Tesira Server IO with an analog input card, a D Series amplifier and an AVB switch. To pass audio through the system you will also need a signal source and a speaker. Create Tesira system configuration 1. Open Tesira software 2.
13. Quick Start Tutorial Compile the system 1. Compile your system by hitting the compile button in the standard Bar or select System > Compilation > Compile active partition Assign physical units to the imaginary units in the system design 1. If the server is already running an old configuration or you are unsure of its state it needs to be reset to become available.
13. Quick Start Tutorial 13.4. Basic Configuration In the Tesira software, double click the amplifier block. The D Series configuration window opens. Here you can check the amplifier for any potential faults and warnings and monitor signal status. You can also control STANDBY/ ON state and other amplifier channel functions such as mute, level and invert. Also, the Auto power down (APD) functionality can be configured (default APD is disabled).
14. Faults and warnings 14. Faults and warnings Category/Type Name On screen text Description Action Increase mains distribution stiffness or reduce output power to avoid limiting ALARM Warning Minor Tesira fault active in the device Warning Under Voltage Limit UVL ACTIVE The Under Voltage limiter is active as the mains supply is approaching the lower end of the device´s operational voltage.
14. Faults and warnings Category/Type Name On screen text Description Action Fault Mains voltage above 270 V MAINS > 270 V Power supply detects mains voltage above operation voltage. Protective shut down, auto restart attempt Check mains distribution/ connection Fault Mains voltage below 65 V MAINS < 65 V Power supply detects mains voltage below operation voltage.
15. Technical Specifications 15. Technical Specifications D 200:4T/Ta D 120:4T/Ta D 80:4T/Ta Tesira® by Biamp / AVB 4 20000 W 12000 W 8000 W Max. Output Power (all ch.’s driven) 1) 2 ohms 2.67 ohms 4 ohms 8 ohms 16 ohms Hi-Z 70 V Hi-Z 100 V 4400 W 5000 W 4400 W 2300 W 1150 W 3300 W 4700 W 3000 W 3000 W 3000 W 1900 W 950 W 3000 W 3000 W 2000 W 2000 W 2000 W 1500 W 750 W 2000 W 2000 W Max output power single channel (all models) 1) 2 ohms 2.
15.
16. Warranty and support 16. Warranty and support 16.1. General This product is manufactured by Lab.gruppen, and it is warranted to be free from any defects caused by components or factory workmanship, under normal use and service, for a period of six (6) years from date of purchase from an authorized Lab.gruppen dealer. If the product fails to perform as specified during the warranty period, Lab.
16. Warranty and support 16.2.2. Factory service In the event a Lab.gruppen product requires factory service, you may contact Lab.gruppen’s service department for return instructions and a Return Authorization number. Please note for product return: 1. Use the original packing. 2. Include a copy of the sales receipt, your name, return address, phone and fax number, email address and description of the defect. 3. Mark the Return Authorization number on the outside of the packing.
Notes Notes D SERIES Tesira Quick Start Guide rev 1.2.
Lab.gruppen adopts a policy of continuous improvement and product specification is subject to change. RPM, R.SMPS, PFC, CDM, BEL, UVL, CAFÉ, ESP, ISVPL, Iso-Float, Raised Cosine, MESA EQ, LimiterMax and LoadLibrary are trademarks of Lab.gruppen AB. Tesira is a trademark of Biamp Systems. All other trademarks remain the property of their respective owners. Copyright © 2015 Lab.gruppen AB. All rights reserved. Item no. QSG-DSERIES-TESIRA labgruppen.