8. Operation with default preset
16
IPD SERIES Operation Manual rev 1.0.0
8. Operation with default preset
An IPD Series amplier may be operated “out of the box” as a standard stereo amplier. For this application, there
is no need to connect the network, download the software, or program a preset in the DSP. Default parameters are
as follows:
Input mixer: Analog 1 and AES 1 routed to channel 1
Analog 2 and AES 2 routed to channel 2
Mode: Stereo
Input levels: 0 dB
Input EQ: Flat
Output EQ: Flat
Delay: Off
Crossover: Off
Output mute: On (muted)
In this mode, the unit will function as a “at” stereo amplier. The outputs may be muted and unmuted with the
front panel buttons. The encoder knob functions as an output gain control, with level adjustable from -47.75 dB
to + 12 dB.
9. IntelliDrive controller overview
9.1. Introduction
IntelliDrive Controller offers fast, intuitive and comprehensive access to the many DSP features offered by IPD
Series ampliers. Although it is possible to program presets and alter existing presets using the front panel controls
(See Section 14), most users will nd the process is easier and more accurate using IntelliDrive Controller. In
most cases, the front panel controls are best reserved for changing presets or making minor level adjustments in
circumstances where a control computer is not available or when network problems are encountered.
Note: This manual assumes the user is familiar with the basic principles of loudspeaker system DSP conguration,
including multi-way loudspeaker system alignment, room tuning, and delay setting. If you are not familiar with these
procedures, we recommend you consult a reference book or online source presenting a comprehensive treatment
of the topic.
9.2. Global (System) View
The Global, or System, View presents a graphical representation of all ampliers connected to the network,
indentied by IP address or user dened name. The Global View gives an at-a-glance overview of amplier groups
and amplier status, including Mute status and output level meters.