LUCIA Operation Manual

13. Set-up and operation
12
LUCIA Operation Manual rev 1.2.0
13. Set-up and operation
13.1. Auto standby / Power-up
urn on automatically when AC power is connected
to the unit; it will go into standby mode if no signal is present at any input for 20 minutes. When in standby, the
reset threshold (-54 dBu) is present at any
channel input.
In order to avoid issues with the signal being too low relative the threshold it is generally better to use full level from
the source and to reduce the gain in the LUCIA instead using the front controls, GPI or in the matrix.
13.2. GPIO configuration: Two output impedance models
All low impedance LUCIA models provide the default functionality described below for General Purpose
Inputs and Output (GPIO).
Remote volume control – The default functionality for the GPI is independent control of output volume (output 1
on GPI1 and output 2 on GPI2). Please note that this control is in series with the control on the front panel. There
are two ways to do this:
A. Connect a GPO from an external control device with a control voltage output of 0 – 3.3 V. The ground of the
control device must be connected to the ground pin of the LUCIA GPI connector.
B. Connect a remote volume control potentiometer per channel to pins 1 through 4 of the GPIO connector as
shown below. (The VCC voltage output is 3.3 V). If you want the link the control, then you simply link GPI1 and
GPI2 together with a jumper cable.
Individual volume control
R
R
Common volume control
R
interrupts normal operation of one or both channels.
Optional GPIO modes – The LUCIA models allow other GPIO functions to be enabled by applying changes to the
amplifier firmware. See “Control Block” in Section 14.5.2.4.
13. Set-up and operation
LUCIA Operation Manual rev 1.2.0
13
13.3. GPIO Configuration: Mono high-impedance models
The Default functionality is as described below for General Purpose Inputs and Output (GPIO).
Remote volume control Connect a remote volume control potentiometer to Ground, GPI1 and Vcc as shown
in the diagram following. Volume control is after input mixing. (The Vcc voltage output is 3.3 V).
Amplifier wake-up Connect an external contact closure to Ground and GPI2 as shown in the diagram follow-
ing. Wake-up happens within 0.5 s after contact closure.
Amplifier status Pins 5 and 6 connect to an internal relay to provide amplifier fault indication. The relay is closed
when the amplifier is on and operating normally. The relay opens if a fault in either channel or in the power supply
interrupts normal operation of one or both channels.
Optional GPIO modes The LUCIA models allow other GPIO functions to be enabled by applying changes to
the amplifier firmware. See “Control block” in Section 14.5.2.4.