LUCIA Operation Manual

15. Appendices
26
LUCIA Operation Manual rev 1.2.0
LUCIA 120/1-70
Level Load Output power Mains Watt *1) Thermal Dissipation
VAC IAC In Out Dissipated BTU/hr kCal/hr
Standby w. remote Power Off.
230 0,032 0,88 0 1 3 1
120 0,027 0,77 0 1 3 1
100 0,028 0,76 0 1 3 1
Power On, Idling
230 0,12 11,9 0 12 41 10
120 0,19 13,0 0 13 44 11
100 0,22 13,1 0 13 45 11
Pink
pseudo
noise (1/8)
70 V 120 x 1 230 0,30 35,6 15 21 70 18
70 V 120 x 1 120 0,47 33,6 15 19 63 16
70 V 120 x 1 100 0,54 34,4 15 19 66 17
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified
here is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.
15. Appendices
22
LUCIA Operation Manual rev 1.1.0
15.4. Thermal dissipation
LUCIA 120/2
Level Load Output power
Mains
voltage
Line
current
Watt *1) Thermal Dissipation
VAC IAC In Out
Dissi-
pated
BTU/hr kCal/hr
Standby w. remote Power Off.
230 0.032 0.88 0 1 3 1
120 0.027 0.77 0 1 3 1
100 0.028 0.76 0 1 3 1
Power on, Idling
230 0.21 11.9 0 12 41 10
120 0.19 13.0 0 13 44 11
100 0.22 13.1 0 13 45 11
Pink Pseudo
Noise (1/8)
16 Ω / Ch. 30 x 2
230 0.22 25.3 7.5 18 61 15
120 0.34 24.3 7.5 17 57 14
100 0.40 24.6 7.5 17 58 15
8 Ω / Ch. 60 x 2
230 0.30 35.6 15 21 70 18
120 0.47 33.6 15 19 63 16
100 0.54 34.4 15 19 66 17
4 Ω / Ch. 60 x 2
230
0.30 36.3 15 21 73 18
120 0.48 34.9 15 20 68 17
100 0.55 35.3 15 20 69 17
2 Ω / Ch. 60 x 2
230 0.32 37.7 15 23 77 20
120 0.50 36.3 15 21 73 18
100 0.57 36.6 15 22 74 19
*1) The ampli ers PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” in the ampli
er providing useful, real-world values of power consumption and heat dissipation.
LUCIA 120/2M
Level Load Output power
Mains
voltage
Line
current
Watt *1) Thermal Dissipation
VAC IAC In Out
Dissi-
pated
BTU/hr kCal/hr
Standby w. remote Power Off.
230 0.032 0.88 0 1 3 1
120 0.027 0.77 0 1 3 1
100 0.028 0.76 0 1 3 1
Power on, Idling
230 0.14 14.8 0 15 51 13
120 0.21 13.4 0 13 46 12
100 0.25 14.1 0 14 48 12
Pink Pseudo
Noise (1/8)
16 Ω / Ch. 30 x 2
230 0.25 28.2 7.5 21 71 18
120 0.35 24.7 7.5 17 59 15
100 0.41 25.6 7.5 18 62 16
8 Ω / Ch. 60 x 2
230 0.33 38.5 15 23 80 20
120 0.47 34.0 15 19 65 16
100 0.55 35.4 15 20 70 18
4 Ω / Ch. 60 x 2
230 0.33 39.2 15 24 83 21
120 0.48 35.3 15 20 69 17
100 0.56 36.3 15 21 73 18
2 Ω / Ch. 60 x 2
230 0.34 40.6 15 26 87 22
120 0.51 36.7 15 22 74 19
100 0.59 37.6 15 23 77 19
*1) The ampli ers PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” in the ampli
er providing useful, real-world values of power consumption and heat dissipation.
15. Appendices
LUCIA Operation Manual rev 1.2.0
27
LUCIA 240/2
Level Load Output power
Mains
voltage
Line
current
Watt *1) Thermal Dissipation
VAC IAC IN Out
Dissi-
pated
BTU/hr kCal/hr
Standby w. remote Power Off.
230 0.032 0.88 0 1 3 1
120 0.027 0.77 0 1 3 1
100 0.028 0.76 0 1 3 1
Power on, Idling
230 0.12 11.9 0 12 41 10
120 0.19 13.0 0 13 44 11
100 0.22 13.1 0 13 45 11
Pink Pseudo
Noise (1/8)
16 Ω / Ch. 60 x 2
230 0.29 34.4 15 19 66 17
120 0.47 34.7 15 20 67 17
100 0.58 34.1 15 19 65 16
8 Ω / Ch. 120 x 2
230 0.42 53.7 30 24 81 20
120 0.70 54.2 30 24 82 21
100 0.81 54.6 30 25 86 21
4 Ω / Ch. 120 x 2
230 0.45 55.2 30 25 86 22
120 0.74 56.7 30 27 91 23
100 0.84 56.8 30 27 91 23
2 Ω / Ch. 120 x 2
230 0.47 59.1 30 29 99 25
120 0.76 58.9
30 29 98 25
100 0.91 61.1 30 31 106 27
*1) The ampli ers PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” in the ampli
er providing useful, real-world values of power consumption and heat dissipation.
LUCIA 240/2M
Level Load Output power
Mains
voltage
Line
current
Watt *1) Thermal Dissipation
VAC IAC In Out
Dissi-
pated
BTU/hr kCal/hr
Standby w. remote Power Off.
230 0.032 0.88 0 1 3 1
120 0.027 0.77 0 1 3 1
100 0.028 0.76 0 1 3 1
Power on, Idling
230 0.14 14.8 0 15 51 13
120 0.21 13.4 0 13 46 12
100 0.25 14.1 0 14 48 12
Pink Pseudo
Noise (1/8)
16 Ω / Ch. 60 x 2
230 0.31 37.3 15 22 76 19
120 0.48 35.1 15 20 69 17
100 0.60 35.1 15 20 69 17
8 Ω / Ch. 120 x 2
230 0.45 56.6 30 27 91 23
120 0.71 54.6 30 25 84 21
100 0.83 55.6 30 26 87 22
4 Ω / Ch. 120 x 2
230 0.47 58.1 30 28 96 24
120 0.75 57.1 30 27 92 23
100 0.86 57.8 30 28 95 24
2 Ω / Ch. 120 x 2
230 0.49 62.0 30 32 109 28
120 0.77 59.3 30 29 100 25
100 0.93 62.1 30 32 110 28
*1) The ampli ers PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” in the ampli
er providing useful, real-world values of power consumption and heat dissipation.