LUCIA Operation Manual

15. Appendices
28
LUCIA Operation Manual rev 1.2.0
LUCIA 240/1-70
Level Load Output power Mains Watt *1) Thermal Dissipation
VAC IAC In Out Dissipated BTU/hr kCal/hr
Standby w. remote Power Off.
230 0,032 0,88 0 1 3 1
120 0,027 0,77 0 1 3 1
100 0,028 0,76 0 1 3 1
Power On, Idling
230 0,12 11,9 0 12 41 10
120 0,19 13,0 0 13 44 11
100 0,22 13,1 0 13 45 11
Pink pseudo
noise (1/8)
70 V 240 x 1 230 0,42 53,7 30 24 81 20
70 V 240 x 1 120 0,70 54,2 30 24 82 21
70 V 240 x 1 100 0,81 54,6 30 25 84 21
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified
here is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.