Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 9. Module File Types & Lake LoadLibrary™
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Global Events and Control
- 24. Keyboard Shortcuts
- 25. External Control Interfaces
- 26. Command Line Options
- 27. Firmware Update
- 28. Preset Manager
- 29. IP Address Reference
- 30. Corporate Information
114
Lake Controller Operation Manual Rev 1.6.1
System Store Recall Menu Reference
To compare the current conguration with one stored in a le:
1. Tap SYSTEM STORE/RECALL.
2. Navigate to the le you wish to compare.
3. Tap the le icon to select it.
4. Tap RECALL COMPARE.
5. Conrm the action by tapping the YES button in the warning message.
This function can help identify any changes that have been made since a le was recalled. Modules with
altered data are identied by a red disc behind their normal icon. This indicates that the Lake Controller is out
of sync with the device.
Figure 7-2: Module Out of Sync Identication
RECALL COMPARE does not overwrite any data in
the device. Audio will not be changed until you tap
the button labeled USE DATA IN CONTROLLER.
7.6 Recall as Virtual Sub System (SS)
The RECALL AS VIRTUAL SS button enables you to work on a system le when no physical units are
connected. All Frames are seen as virtual. Once the system has been designed, the Virtual Frames can be
replaced by physical Frames.
This function adds the Modules, Super Modules and Groups from the selected le to the current system
conguration as virtual Modules.
The button will read RECALL AS VIRTUAL SS on screen resolutions of 1024 x 768 or less; the full label
RECALL AS VIRTUAL SUB SYSTEM will be displayed on higher resolution screens.
When recalling a Dante-configured system as a Virtual Sub System, all
devices receive new default Dante Device names to ensure no conflicts
occur if the same system is recalled multiple times. Dante receivers will
subscribe to the same Dante channels prior to the virtual recall.