Lake Controller Operation Manual

Table Of Contents
Lake Controller Operation Manual Rev 1.6.1
Modules Menu Reference
147
Figure 8-25: AES Output Sample Rate Conguration (LM Series / MY8-LAKE)
Please refer to section 8.2.1 for further information on Digital Clock Conguration.
For all output types, the number of channels varies depending on
the options available for the selected device.
Dante Output Configuration
For Dante outputs the DANTE CONFIGURATION screen is displayed. Please refer to section 4.3.6 for
further details regarding Dante.
Disconnecting Outputs for Output Type
Tapping the DISCONNECT ALL icon will disconnect all outputs for the currently selected destination
output type. For example, if ANALOG is the currently selected output type, tapping this button will discon-
nect all analog outputs from any source they are currently connected to. A warning dialog is displayed for
conrmation on this action.
Bridge Mode Configuration (Lake-enabled Amplifier only, except D 10:4L, D 20:4L and D 40:4L)
To activate power output channel bridge mode on a Lake-enabled amplier, tap the blue Bridge button on
the Output Conguration page as shown in the image on the left in Figure 8-26. The Bridge button turns
orange and the output selectors merge to indicate bridge mode is active. To deactivate output channel
bridge mode, tap the orange Bridge button again.