Lake Controller Operation Manual

Table Of Contents
Lake Controller Operation Manual Rev 1.6.1
Modules Menu Reference
153
8. 2 .12 Interactive Signal Path Block Diagram
The signal path of each Module is shown in Graphical form on the right of the I/O CONFIG page. Each of the
blocks can be selected to navigate directly to the associated EQ/LEVELS/XOVER/AUX/HPF/LPF screens.
After using the interactive block diagrams to access
the other screens, the EQ/LEVELS EXIT button
returns you to the I/O CONFIG page instead of
HOME.
8. 2 .13 Input Selection (MY8-LAKE in Simplified View Only)
The MY8-LAKE device has a unique simplied view for the Mesa Frame conguration by default. In this
view the input can be easily toggled between default Host output and AES input. Please refer to “8.2.7.2
Input Mixer” on page 142 and “22.4 I/O Conguration View Mode Options” on page 279 for further
information.
8. 2 .14 Frame Config/Soft Reset
For Lake-enabled ampliers this button reads SOFT RESET and resets the device to its factory default state,
without removing any presets stored in the device, and without resetting the networking conguration data
including IP Cong, IP Address, Subnet Mask & Dual Redundancy settings.
For LM Series and MY8-LAKE devices, this button reads FRAME CONFIG and provides a sub-menu
allowing the device to be congured as:
CONTOUR (2-Contour Modules for LM Series; 4-Contour Modules for MY8-LAKE)
MESA EQ (4-Mesa EQ Modules for LM Series; 8-Mesa EQ Modules for MY8-LAKE)
CONTOUR/MESA EQ (2-Contour Modules and 4-Mesa EQ Modules for MY8-LAKE)
For all products, configuring or resetting a device via
the Lake Controller retains the current IP address
setting and system/Frame presets.
8.3 Label & Lock
From the Modules menu, tap LABEL & LOCK to view a submenu with functions to label a Module or Frame
and allow a system designer to lock Module and base congurations