Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 9. Module File Types & Lake LoadLibrary™
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Global Events and Control
- 24. Keyboard Shortcuts
- 25. External Control Interfaces
- 26. Command Line Options
- 27. Firmware Update
- 28. Preset Manager
- 29. IP Address Reference
- 30. Corporate Information
156
Lake Controller Operation Manual Rev 1.6.1
Modules Menu Reference
4. Tap a Module from an unused Frame then tap COMPLETE REPLACE.
To locate a particular device, tap the SEL button on the front panel to center the unit on the scroll bar:
▸ LM Series | Press the top-left dynamic function button on the front panel
▸ PLM Series | Press the second dynamic function button down on the left on the front panel
▸ PLM+ Series | Press the top-left dynamic function button on the front panel
▸ D Series | Press the SELECT button to the far-right of the front panel
8.4. 3.1 Replace Frame Rules and Compatibility
▸ All Modules of a Frame must be present on the Module scroll bar (i.e. no part of the Frame can be in
use in the current system conguration)
▸ Network IP settings and Dual Redundancy conguration are not transferred during a Frame Replace
operation; congure this manually on the destination Frame.
▸ PLM 10000Q and PLM 20000Q Frames may be replaced with PLM+ or D Series, and will populate
Modules A&B only. Modules C&D will remain unaffected.
▸ PLM+ or D Series may be replaced with any product from either of these product lines without any
loss of data. If a destination model cannot set a value contained in the source model, the appropriate
minimum or maximum will be set and these discrepancies are indicated via the desired values and
actual values within brackets [ ]. These products may not be replaced by a legacy PLM product.
▸ PLM 14000 can only be replaced with an online PLM 14000.
▸ For LM Series and MY8-LAKE devices, the source and destination Frames must be of the same
conguration type (i.e. Contour, Mesa, or Contour/Mesa), and can only be replaced with a Frame of the
same product type.
8.4.4 Complete Replace
This button completes the REPLACE FRAME function. This function is active only when the REPLACE
button is selected and a destination Module has been selected from the Module scroll bar.
Data from the source Frame is transferred to the destination Frame and the Frame from the scroll bar will
now take the place of the source Frame in the system conguration.
If the source Frame is online, all Modules in the work area are returned to the scroll bar.