Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 9. Module File Types & Lake LoadLibrary™
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Global Events and Control
- 24. Keyboard Shortcuts
- 25. External Control Interfaces
- 26. Command Line Options
- 27. Firmware Update
- 28. Preset Manager
- 29. IP Address Reference
- 30. Corporate Information
176
Lake Controller Operation Manual Rev 1.6.1
Module File Types & Lake LoadLibrary™
Figure 9-8: Linear Phase 2-Way + 1-Auxiliary Outputs
9.5.2 Linear Phase 3-Way
The Linear Phase 3-Way (LP3way) has a similar signal path to the Classic 3-Way (CL3way).
Figure 9-9: Linear Phase 3-Way
9.5.3 Linear Phase 2-/3-Way EQ/MaxPeak combinations
The LP2 and LP3way Modules use a signicant amount of processing power to create steep crossovers
with at phase response. For this reason, the full amount of output-specic EQ lters can only be used if the
MaxPeak is disabled on the Module, as the MaxPeak Limiter also requires a large amount of processing.
The MaxPeak Limiter process is disabled when the total MaxPeak level (including Group and factory set-
tings) is 25 dBu or greater. The following crossover EQ lters for the LP2 and LP3way are available:
▸ MaxPeak Activated: 10 EQ Filters + High-pass Filter
▸ MaxPeak Deactivated: 15 EQ Filters + High-pass Filter