Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 9. Module File Types & Lake LoadLibrary™
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Global Events and Control
- 24. Keyboard Shortcuts
- 25. External Control Interfaces
- 26. Command Line Options
- 27. Firmware Update
- 28. Preset Manager
- 29. IP Address Reference
- 30. Corporate Information
Lake Controller Operation Manual Rev 1.6.1
Global Events and Control
285
23.2.2 Global Power Channel Mute Control
Two buttons, ALL MUTED and ALL UNMUTED, indicate and control the power channel mute status across
all Lake-enabled ampliers that are online and present in the current system conguration. A conrmation is
required prior to changing this status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status.
Status indicators to the right of the buttons show the total number of power channels in the current system
conguration that are MUTED, UNMUTED or OFFLINE.
23.2.3 Global Temperature
The current ambient temperature (the temperature of the air surrounding the cabinets) may be entered on
this tab. Tapping on the blue button in the AMBIENT TEMPERATURE box opens a numeric keypad for the
purpose.
The temperature value is transferred to the LOADSmart Table on the MODULE LOADSmart Tab and used
for load verication and monitoring procedures. Buttons allow selection of temperature display in degrees
CELSIUS or FAHRENHEIT.
23.2.4 Global LoadSmart
The GLOBAL LOAD CONTROL VERIFY button initiates the system-wide load verication of all Frames.
23.2.5 Global Dual Redundancy Control
Two buttons, ON and OFF, control the Dual Redundancy network status of all devices that are online and
present in the current system conguration (not applicable to MY8-LAKE). A conrmation is required prior to
changing this status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status.
Status indicators summarize the number of online devices in the current system conguration that have this
status set to ON or OFF.
The power must be cycled on the device for this
parameter change to complete. (i.e. Disconnect or
turn off mains power then reconnect or turn on
mains power).
Please refer to section 8.2.10.5 for further information regarding Dual Redundancy.