Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 9. Module File Types & Lake LoadLibrary™
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
Lake Controller Operation Manual Rev 1.5.8
EQ/Levels Menu Reference
95
While most of the button bar functions are the same, some XOVER menu options and functions are differ-
ent for linear phase Modules. These differences are identied in the following sections.
6.4.5 Crossover Functions
CROSSOVER FUNCTIONS provides a submenu containing the following functions:
6.4.5.1 HPF/LPF Functions
▸ HPF/LPF FUNC EXIT exits this menu and returns to the CROSSOVER FUNCTIONS menu.
▸ INPUT HPF SETs the HPF to affect all output channels for the Module (depending on the frequency of
the HPF and outputs). Applicable to Contour Modules only.
▸ LOW OUTPUT HPF SETs the HPF to affect only the lowest output channel of the selected Module.
Applicable to Contour Modules only.
▸ HPF ENABLE enables/disables the HPF for the selected Module.
▸ LPF ENABLE enables/disables the LPF on the highest output channel for the selected Module.
INPUT HPF and LOW OUTPUT HPF are disabled for
the Linear Phase Brick Wall 4-Way Module. The
LP4way HPF is fixed to INPUT HPF. Other Module
types, incl. LP2/LP3way provide the HPF option.
6.4.5.2 Crossover Hide
Available only in Designer Mode. When enabled (orange), the crossover page will be hidden when the
Module is locked, or after exiting from Designer Mode.
6.4.5.3 Crossover View Only
Available only in Designer Mode. When enabled (orange), the crossover page will be set as view only when
the Module is locked, or after exiting from Designer Mode.
6.4.5.4 EQ Preferences
This provides a submenu containing options regarding the view of the EQ scale.