Lake Controller Operation Manual

Table Of Contents
132
Lake Controller Operation Manual Rev 1.5.8
Modules Menu Reference
To change the currently selected breaker type, tap the required breaker on the scrolling bar at the bottom of
the screen then tap again in the Breaker Type box at the top of the screen.
Model Current (Amps) Fuse Options Available
D 200:4L 5-32 Conservative, Fast, Universal
D 120:4L 5-25 Conservative, Fast, Universal
D 80:4L 5-15 Conservative, Fast, Universal
D 40:4L 2-15 Conservative, Fast, Universal
D 20:4L 1-7 Universal
D 10:4L 1-7 Universal
PLM+ 5K44 2-15 Conservative, Fast, Universal
PLM+ 12K44 5-25 Conservative, Fast, Universal
PLM+ 20K44 5-32 Conservative, Fast, Universal
PLM 20000Q 5-32 Conservative, Fast, Universal
Table 8-2: Nominal current range and fuse options by product
8.2.5 Dante Configuration (not applicable for MY8-LAKE)
The Dante Conguration (named “Dante and AES67 Conguration” for all AES67 enabled models) summary
on the I/O CONFIG screen reports either the Global Dante Clock Sample Rate, or advises that Dante is
disabled. When disabled, the device does not support transmitting or receiving any networked audio.
Itadditionally lists the assigned receiver subscriptions and associated sample rate and status.
Further information on Dante settings can be accessed by tapping the zoom button or the associated
text. A screen similar to that shown in Figure 8-12 will be displayed. All settings available under
Dante Conguration are stored in System les, Frame Presets and are set on any Frame Replace/
BATCH REPLACE operation.
To congure the device for Dante dual redundant operation, navigate to the TECHNICAL DATA screen via
the I/O CONFIG menu and enable the Dual Redundancy option. This change will require a power cycle of
the device; please refer to section 8.2.10.5.
8.2 . 5.1 Device Tab
Tapping the zoom button labeled DANTE CONFIGURATION displays the Dante Conguration > Device tab,
with Dante disabled by default: