Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 9. Module File Types & Lake LoadLibrary™
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
152
Lake Controller Operation Manual Rev 1.5.8
Modules Menu Reference
8. 2 .12 Interactive Signal Path Block Diagram
The signal path of each Module is shown in Graphical form on the right of the I/O CONFIG page. Each of the
blocks can be selected to navigate directly to the associated EQ/LEVELS/XOVER/AUX/HPF/LPF screens.
After using the interactive block diagrams to access
the other screens, the EQ/LEVELS EXIT button
returns you to the I/O CONFIG page instead of
HOME.
8. 2 .13 Input Selection (MY8-LAKE in Simplified View Only)
The MY8-LAKE device has a unique simplied view for the Mesa Frame conguration by default. In this
view the input can be easily toggled between default Host output and AES input. Please refer to “8.2.7.2
Input Mixer” on page 141 and “22.4 I/O Conguration View Mode Options” on page 289 for further
information.
8. 2 .14 Frame Config/Soft Reset
For Lake-enabled ampliers this button reads SOFT RESET and resets the device to its factory default state,
without removing any presets stored in the device, and without resetting the networking conguration data
including IP Cong, IP Address, Subnet Mask & Dual Redundancy settings.
For LM Series and MY8-LAKE devices, this button reads FRAME CONFIG and provides a sub-menu
allowing the device to be congured as:
▸ CONTOUR (2-Contour Modules for LM Series; 4-Contour Modules for MY8-LAKE)
▸ MESA EQ (4-Mesa EQ Modules for LM Series; 8-Mesa EQ Modules for MY8-LAKE)
▸ CONTOUR/MESA EQ (2-Contour Modules and 4-Mesa EQ Modules for MY8-LAKE)
For all products, configuring or resetting a device via
the Lake Controller retains the current IP address
setting and system/Frame presets.
8.3 Label & Lock
From the Modules menu, tap LABEL & LOCK to view a submenu with functions to label a Module or Frame
and allow a system designer to lock Module and base congurations