Lake Controller Operation Manual

Table Of Contents
Lake Controller Operation Manual Rev 1.5.8
Modules Menu Reference
159
screen is displayed to enable conrmation of output routing - this setting can be changed by toggling the
option on the Output Conguration screen.
By default, a Module recall will remove the Module from any assigned Groups and a warning will be
displayed to conrm this action. If the Keep Group Assignment option is enabled, the assignment of the
Module to the Group will be maintained during the Module recall.
Figure 8-31: Recalling a Module File
Recalling a Module file overwrites all data currently
stored in the selected Module and if “Keep Group
Assignment” is not enabled it will also remove the
Module from any Groups.
EAW
®
Greybox
TM
file (.gyx) may also be recalled
directly into the Modules of Lake-enabled
amplifiers. Please refer to chapter 9 for further
details.
8.6.2 Store
The STORE button stores over an existing le. This button is active only when a le is selected.
1. Tap an existing le to store over (overwrite).
2. Tap STORE.
3. Conrm the action by tapping the YES button in the warning message.
If the selected file is set to READ ONLY, the STORE
function is gray (inactive).
8.6.3 New Store
The NEW STORE button stores the current Module conguration under a new le name.
1. Navigate the le system, and tap the desired destination folder to select it.
2. Tap NEW STORE.