Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 9. Module File Types & Lake LoadLibrary™
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
Lake Controller Operation Manual Rev 1.5.8
Network Menu Reference
197
15.2 Multiple Controllers
15.2 .1 Overview and Menu Options
The Lake Controller system allows multiple Controllers to be connected to the same network. When in this
mode, certain functionality is restricted.
The rst Controller to connect to a network is called the primary Controller. Any subsequent Controllers are
referred to as secondary Controllers.
The following options are available on the MULTIPLE CONTROLLERS submenu:
15. 2.1.1 Multi Cont Enable
This button is available only on the primary Controller and is disabled (gray) on any secondary Controllers.
When this button is active (orange), multiple Controllers are allowed on the same network. When the button
is inactive (blue), only one Controller is allowed on the network.
15.2.1.2 Confirmation Required
This button is available only on the primary Controller and is disabled (gray) on any secondary Controllers.
When this button is active (orange), a conrmation dialog box is displayed on the primary Controller when a
secondary Controller attempts to connect. If this button is inactive (blue), then additional Controllers are able
to connect to the network without primary Controller approval.
15. 2.1.3 Analyzer Enable
This button provides the option to disable analyzer data on a per-controller basis (useful when using multiple
Controllers). If this button is active (orange), analyzer data will be displayed on this Controller. If this button is
inactive (blue), analyzer data will not be displayed. This button is disabled (gray) if the analyzer is not avail-
able.
15.2.2 Primary and Secondary Controllers
The primary Lake Controller communicates with the network of Lake devices, and also with secondary
Controllers. The secondary Controllers communicate only via the primary Controller.
Primary and Secondary Controllers can be used in either Designer or User Mode (in which various Designer
Mode functions will be restricted). The Primary Controller must have a connection to the network for
Secondary Controllers to function.