Lake Controller Operation Manual
106
Lake Controller Operation Manual Rev 1.7.0
EQ/Levels Menu Reference
Linear phase crossovers, or combined Classic
crossovers, cannot be bypassed. To bypass the
Module’s overall HPF or LPF, toggle the HPF
ENABLE / LPF ENABLE button.
6.4.10 Filter Flat
The FILTER FLAT button is active only when a PEQ lter is selected. The function is inactive if a crossover is
selected. Tap FILTER FLAT to set the lter gain to zero and leave frequency/bandwidth unchanged.
6.4.11 Filter Delete
The FILTER DELETE button is active only when a PEQ lter is selected. The function is inactive if a cross-
over is selected. Tap FILTER DELETE to remove the selected PEQ lter from the overlay.
6.4.12 Analyzer Tap to Search
Please refer to section 6.3.14 for details on this function.
6.5 Auxiliary Output Channels
Contour Modules provide various options to congure channels as auxiliary outputs. Up to 12 individually
congured auxiliary outputs can be created. The Auxiliary Output Module les allow full-bandwidth custom
settings to be congured by the user. Independent Aux tabs are provided for each output channel instead of
a unied crossover tab. These tabs are provided in addition to the input EQ overlays (PEQ/BLEQ/GEQ) that
still apply to all outputs for the Module.
Because a different process is used to calculate output-specic EQ, the Mesa lter is not available. How-
ever, in addition to low-shelf, high-shelf, and Parametric lters, the Auxiliary Output Modules provide both
low-pass and high-pass lters. In Designer Mode, all-pass lters are also available.
6.5.1 Auxiliary Output Module Types and Combinations
This section describes the available Auxiliary Output Module types along with the combinations of Modules
that are allowed.
6.5.1.1 One Auxiliary Output
The 1-Auxiliary Outputs Module is automatically recalled into Module B/D when a Classic 5-Way Module is
recalled into Module A/C. This Module type cannot not be used in Module A/C.