Lake Controller Operation Manual

150
Lake Controller Operation Manual Rev 1.7.0
Modules Menu Reference
To maintain cross-compatibility, if a frame preset/replace results in
bridge mode activation for D 10:4L, D 20:4L or D 40:4L the Bridge
function will still show as enabled although these outputs are no
longer bridged. This is identied by separated output selector icons
as shown in the image to the right in Figure 8-26.
Figure 8-26: Bridge Mode (Lake-enabled ampliers only)
When Bridge Mode is activated, CLASS 3 WIRING is required.
Please refer to the Operation Manual for additional wiring informa-
tion.
8.2.9 Latency Match
This button is available on all devices except MY8-LAKE. It is blue when disabled and orange when enabled.
This feature adds additional latency to the output signal to align latency with PLM Series devices.
LATENCY MATCH is based on the following criteria:
Input types for all devices are identical (Analog or AES only).
Input sample rates for all devices are identical where AES inputs are being used.
Outputs are set to analog.