Lake Controller Operation Manual

Lake Controller Operation Manual Rev 1.7.0
Designer Mode Menu Reference
255
Figure 19-16: Locking Polarity
When the Module is locked, the worksheet will appear as shown Figure 19-17. In this example, output
polarity for channels 2, 3, and 4 will be locked even in Designer Mode.
Figure 19-17: Polarity Locked
Designer worksheets are not available in User Mode, and in the example shown in Figure 19-17, only the
input and low output polarity buttons will be visible.
19.4.6 PEQ - Design
The PEQ-DESIGN worksheet displays the details for each PEQ overlay for the selected Lake device. Table
19-6 shows the available PEQ type abbreviations, descriptions, and default values.
Table 19-6: PEQ Types
EQ TYPE DESCRIPTION GAIN FREQUENCY BANDWIDTH
LS Low Shelf 0 dB 125 Hz 1.9
BP
Band-pass
(Parametric)
0 dB 500 Hz 0.33
ME Mesa Filter
0 dB 830 Hz 0.33
0 dB 1.2 kHz 0.33
HS High Shelf 0 dB 8 kHz 1.9