Lake Controller Operation Manual
Lake Controller Operation Manual Rev 1.7.0
Lake-enabled Amplifier Reference
271
Figure 20-10: Output Tab
20.10.1 Amplier Gain
The amplier gain parameter on the Output tab relates to the power output stage of the amplier.
This gain is set per Module output channel, and it part of Speaker Preset les created for Lake-enabled
ampliers. Any power output channel routed to a Module output will inherit the Amplier Gain value speci-
ed for that Module output.
To change the amplier gain for a channel, tap on the associated cell and enter a value via the pop-up
numeric keypad. Entering a value in the ALL cell applies that value to all power output channels.
Amplier gain may also be set via the front panel via MENU > MODULE > AMP GAIN on PLM and PLM+
devices only.
20.10.2 Inter-Sample Voltage Peak Limiter (ISVPL) Threshold
The ISVPL threshold information is displayed in the second row of the Control tab table.
Blue text indicates the desired value; white text within block parenthesis indicates the actual value for each
power output. The actual value per power output channel can be affected by:
▸ The ISVPL Threshold