Lake Controller Operation Manual
Lake Controller Operation Manual Rev 1.7.0
IP Address Reference
325
▸ Dante specic documentation included in the Lake Controller software installation
▸ Lake Processing forum @ http://support.labgruppen.com/home
If desired, you can also use Class A (except for PLM+), Class B (recommended) or Class C private IP ad-
dress ranges. These addresses require additional conguration, and thus more knowledge of IP addresses
and networking. Table 29-1 shows a selection of private IP address ranges recommended for use with the
Lake device and Lake Controller network. It is recommended that all hardware is congured with a private IP
address within these ranges.
Class Range
A 10.x.x.x
B 169.254.x.x (Default - Automatic Private IP Address) - RECOMMENDED
C 172.16.x.x through 172.31.x.x*
D 192.168.0.x through 192.168.255.x
Table 29-1: Recommended Private IP Addresses
**For PLM and LM Series, 172.31.x.x is used on the secondary computer’s
network interface for Dante Dual Redundancy conguration. PLM+ and D
Series have this as default, but for these devices it is possible to congure it
freely. . Please refer to chapter 3 for further details.
Lake devices and Lake Controllers can be congured to communicate over a network using any IP address
and subnet mask combination required for your particular application. More sophisticated networks that
include trafc from other professional and consumer equipment must be congured correctly to achieve
desired operation.
IP Address & Dual Redundancy settings can only be
changed either manually by the user via software, or via a
Factory Reset. These parameters are unaffected by
SYSTEM RECALL, Preset Recall, Frame Replace,
SOFT RESET etc.