Lake Controller Operation Manual
Lake Controller Operation Manual Rev 1.7.0
Lake Controller Tutorial
57
5. Tap YES in the dialog box to load the new crossover.
Figure 4-51: Changing the crossover slope
The crossover interface provides a fast and easy method for conguring your loudspeaker system. You can
create your own presets or build them based upon data available from speaker manufacturers.
For XP modules 2-way, 3-way and 4-way, the XOVER screen has an Output selector available in the top right
corner where the specic output is selected.
4.6 Groups
The Lake Controller allows Grouping of multiple Modules. This unique concept allows the EQ and levels
of multiple Modules to be changed with a single adjustment. Every Module may be a member of up to 28
Groups.
All EQ functions available for a Module are also available for a Group, with a maximum of four EQ overlays
per Group.
Most Levels functions are also available for Groups, except the following:
▸ LimiterMax RMS Corner
▸ LimiterMax RMS Attack
▸ LimiterMax RMS Release
▸ Input Headroom
▸ Control of output levels where the Group contains Modules of varying crossover types (e.g. 3-Way and
4-Way Modules assigned to the same Group).