Lake Controller Operation Manual

Lake Controller Operation Manual Rev 1.7.0
Lake Controller Tutorial
57
5. Tap YES in the dialog box to load the new crossover.
Figure 4-51: Changing the crossover slope
The crossover interface provides a fast and easy method for conguring your loudspeaker system. You can
create your own presets or build them based upon data available from speaker manufacturers.
For XP modules 2-way, 3-way and 4-way, the XOVER screen has an Output selector available in the top right
corner where the specic output is selected.
4.6 Groups
The Lake Controller allows Grouping of multiple Modules. This unique concept allows the EQ and levels
of multiple Modules to be changed with a single adjustment. Every Module may be a member of up to 28
Groups.
All EQ functions available for a Module are also available for a Group, with a maximum of four EQ overlays
per Group.
Most Levels functions are also available for Groups, except the following:
LimiterMax RMS Corner
LimiterMax RMS Attack
LimiterMax RMS Release
Input Headroom
Control of output levels where the Group contains Modules of varying crossover types (e.g. 3-Way and
4-Way Modules assigned to the same Group).