Designer Mode Menu Reference
19.3.1.3 All Pass Filters
In Designer Mode, the All Pass lter is available on the XOVER/AUX screens. The All Pass lter icon is
identied at [A] in Figure 19-7:
Figure 19-7: All Pass Filter
The ALL PASS lter allows rst- and second-order (default) phase adjustment with variable bandwidth and
frequency.
To add an ALL PASS lter to an output, perform the following steps:
1. Select an output on the Xover page, or select the required Aux Output screen.
2. Tap the ALL PASS lter icon [A].
3. Tap on the EQ scale to add the lter.
4. Adjust the order, frequency, and bandwidth as required.
19.3.2 EQ Functions
19.3. 2 .1 Set Hide/View Only Status for an Individual EQ Overlay
1. Navigate to the Module or Group overlay in EQ/LEVELS.
2. Tap EQ OVERLAY FUNCTIONS, then EQ OVERLAY PROPERTIES.
3. Tap EQ OVERLAY VIEW ONLY or EQ OVERLAY HIDE. The selected status is illuminated orange.
19.3.2.2 Set Hide/View Only Status for All EQ Overlays
This affects all EQ overlays in the current system conguration.
1. From HOME, tap USER PREFERENCES.
2. Tap GLOBAL ACCESS.
3. Tap EQ HIDE/EQ VIEW ONLY.