Lake Controller Operation Manual

Lake Controller Operation Manual Rev 1.5.4
EQ/Levels Menu Reference
71
The MaxPeak limiter process is disabled when the total MaxPeak level (including Group and factory settings)
is 25 dBu or greater.
An orange bar moves downward from the top of the channel meter to indicate the limiting amount. To adjust
Limiter MaxPeak values, drag the fader (D) for large increments, drag above or below the fader for ne
adjustment, or tap the value (A) for keyboard entry.
The MaxPeak Level value is relative to the factory MaxPeak value (dBu-pk). While dragging the fader, the
total value is displayed in the status bar as dBu-pk, dBV-pk, and Vpk
6.2.4 Enable Mute
This button locks and unlocks the mute buttons and is active by default (that is, muting or unmuting is
allowed). When the button is active (orange), channel muting via the Controller is enabled. When the button
is inactive (blue), channel muting is disabled.
6.2.5 Enable Polarity
This button locks or unlocks the polarity buttons and is inactive by default (polarity buttons locked). When
the button is active (orange), the polarity can be changed. When the button is inactive (blue), the polarity
cannot be changed.
If a system designer has locked polarity changes on
one or more outputs, the polarity button for the
outputs will not be displayed in User mode.
6.2.6 Label Channel
This function applies to Modules only and is inactive if a Group is selected. Channel labels for Groups are
derived from the Module that has been assigned for metering purposes as just described.
The channel label is a user-dened value that appears on the mute button at the bottom of each channel,
the Module I/O CONFIG page, and on any auxiliary output EQ tabs.
To label a channel:
1. Access a Module levels page through a Module icon.
2. Tap LABEL CHANNEL, then tap the required channel label/mute button.
3. Enter the channel label using the on-screen keyboard (or an external keyboard).