Module B label and input gain meter
Main Voltage and Ampere Meter (PLM 20000Q ONLY)
Output 1: V - Voltage Meter I - Current Meter P - Power Meter L - Gain Reduction Meter
Output 2: V - Voltage Meter I - Current Meter P - Power Meter L - Gain Reduction Meter
Output 3: V - Voltage Meter I - Current Meter P - Power Meter L - Gain Reduction Meter
Output 4: V - Voltage Meter I - Current Meter P - Power Meter L - Gain Reduction Meter
The Voltage Meter (V) indicates the PLMs power output stage voltage relative to its clip level
The Current Meter (I) indicates the current the power output stage is driving into its load, relative to the
maximum permissible current the xed CPL allows
The Power Meter (P) indicates the instantaneous output power being developed in the load relative to
the PLMs maximum output power capability.
The Gain Reduction Meter (L) indicates the degree of limiting being applied by the PLM ISVPL and/or
the Lake LimiterMax.
7.10.3 Temperature View
Temperature View provides information about the current operating temperatures within the PLM and the
connected loudspeakers.
Figure 7-7: Meter Mode > Temperature View
Current View title. Power supply temp (PSU) & Lake processor temp (DSP) as percentage of maximum
Unused in Temperature View
Unused in Temperature View